EFA7 electric field detector

PRODUCTS AND SOLUTIONS FOR MONITORING AND CONTROL IN THE ENERGETICS

EFA7 - Personal Detector of Proximity to Dangerous Voltage

General description

The purpose of the EFA7 handheld electric field detector is to provide an early indication of the proximity of dangerous medium voltages (typically from 6 to 110 kV), 50 Hz (optionally 60 Hz), to prevent electric shock due to unwanted violation of the safety distance. The detector measures the level of the fundamental harmonic intensity of the alternating electric field and, if the set level is exceeded, immediately alerts the worker by a strong signal to the dangerous situation so that he can react in time. In the case of high voltages (over 110 kV), the strength of the electric field is so high that it is not possible to set the sensitivity to such a low level and therefore in these cases the device can only be considered as detecting the presence of voltage in a object.

The EFA7 is available in two cases, the red one is suitable for conventional wrist wear, the black one offers the use of straps of different lengths and therefore the possibility of wearing it over work clothing.

Basic features

  • signaling of dangerous approach to a place where medium voltage is present,
  • IP67 smartwatch case,
  • wrist attachment,
  • suitable for outdoor and indoor electrical work,
  • an additional level of protection to prevent electric shocks,
  • light, sound and vibration alarm,
  • configurable levels of electric field detection according to the used voltage levels of distribution networks,
  • detector settings and FW update via Bluetooth,
  • support application for mobile devices – Android OS,
  • active mode is automatically switched on by user´s movement – detected by accelerometer,
  • automatic shutdown after 1 hour of inactivity,
  • battery life approx. 40 hours of active mode,
  • wireless charging according to Qi standard,
  • the charging base is an optional accessory and is powered via USB,
  • battery status indication,
  • operating temperatures -20 to +60 °C,
  • charging temperatures 0 to +45 °C,
  • relative humidity 20 to 90% non-condensing,
  • weight 65 g (without packaging).

Reasons to purchase the product

  • the failure of standard security measures can never be completely prevented,
  • if the device is used correctly, this precaution is not dependent on human factors,
  • it is the last warning when other measures fail.

Contact form